Old 01-30-2020, 09:31 AM   #6
S14rebuild
BANNED
 
Join Date: May 2019
Location: Florida-FAIL
Posts: 2,495
Trader Rating: (8)
S14rebuild S14rebuild S14rebuild S14rebuild S14rebuild S14rebuild S14rebuild S14rebuild S14rebuild S14rebuild S14rebuild
If you have 12v+ to the main terminal on the starter, and u apply 12v to the solenoid n nothing happens like you stated, then you have a bad ground. Check ground from battery to chassis, and engine to chassis grounds. Not on the ends of the cable, but the cables themself.

Easiest way to verify is to use jumper cables to temporarily be used as ground straps. Id go directly from negative terminal on battery to bellhousing bolt.


As issuses with the other electronics id say there a ground issue as well.
S14rebuild is offline   Reply With Quote